Roof Window Sizes Guide: How to Order the Correct Sizing

Ordering the wrong size is one of the most expensive mistakes on any roof project. This roof window sizes guide shows builders, roofers and DIY homeowners exactly what to measure and when. You will learn the difference between the structural opening and the external kerb, so you can order with confidence. Use this roof window sizes guide before you cut any timber, and your rooflight should fit first time. 

Roof Window Sizes Guide: Structural Opening vs External Kerb Size 

The most common sizing error comes from mixing up two different measurements. This roof window sizes guide separates them clearly. 

The internal structural opening is the clear hole in your roof timbers, measured in millimetres (mm). It is formed by the trimmer timbers around the opening. The external kerb dimension is the overall size of the rooflight frame or upstand that sits on top of the roof. It is usually larger than the opening, often by 100 to 200mm each way, though this varies by product. 

Understanding structural opening vs rooflight size is vital. Always check the manufacturer’s drawing, as the size you order may refer to either measurement.

Term 

What It Means 

Why It Matters 

Internal structural opening 

Clear hole between trimmer timbers 

Set before the roof is finished 

External kerb dimension 

Overall outer size of frame or upstand 

Needed for roofing and flashing details 

Glass size 

Visible glazed area 

Affects daylight, not fixing 

How Do You Measure a Flat Roof Opening for a Skylight Unit? 

To measure a flat roof opening for a skylight, record the internal structural opening width and length in millimetres between the finished trimmer timbers. Check each at three points, measure both diagonals to confirm it is square, and compare the results with the manufacturer’s drawing. 

Here is how to measure for a skylight in five steps: 

  • Measure the width at the top, middle and bottom of the opening. 
  • Measure the length at both sides and the centre. 
  • Measure both diagonals. They should match within a few millimetres. 
  • Note the depth of the roof build-up and upstand height. 
  • Write down every figure in mm and mark which is which. 

Measure Before Plasterboarding Is Complete 

This is the most important rule in the guide: take your structural opening dimensions before plasterboarding is complete. Once boards, insulation and finishes go on, the true opening is hidden and harder to check. Measuring early lets you correct timber errors cheaply. 

Again, measure before plasterboard goes up. Then confirm the sizes with your supplier, and only then fix the finishes. The Federation of Master Builders (FMB) advises checking critical dimensions on site, rather than relying on drawings alone. Our team can send structural kerb drawings for your chosen unit, so you can match your timber work to the product. 

Standard Rooflight Sizes UK vs Custom Skylight Dimensions 

Many projects can use standard rooflight sizes UK suppliers hold in stock. These are the fastest and most economical route, and our standard UK stock sizes are ready for next-day dispatch. Browse our standard flat roof skylights to see current sizes. 

Some roofs need something different. Custom skylight dimensions suit unusual openings, long runs of glass or period properties. Our precision millimetre manufacturing means bespoke sizes arrive accurately made. Use our made-to-measure size calculator to explore sizes within your range, then confirm everything against your site measurements. 

Joist Spacing: Modern Builds vs Historic Roofs 

UK modern builds usually have joists at 400mm or 600mm centres. With typical 47mm joists, that leaves a clear gap of roughly 353mm or 553mm between them. Rooflights are often sized to fit between joists, or to span them using trimmer timbers. 

Historic buildings are less predictable. Old roof structures may have uneven spacing, irregular rafters or timbers of different sizes. In these cases, measure every opening individually and consider custom skylight dimensions. Our guide to custom rooflights for different roof designs explains how bespoke sizing suits unusual structures. 

Allowing for Thermal Expansion and Seasonal Movement 

Timber and rooflight frames move slightly with the seasons. Roofs heat up in summer sun and cool sharply in winter. A small clearance gap around the unit lets the frame expand without stress. Many manufacturers suggest a few millimetres of tolerance per side, but always follow your product’s instructions. 

BS 8213-4, the code of practice for installing windows, doors and roof windows, supports careful installation and proper tolerances. The Glass and Glazing Federation (GGF) also promotes correct fitting practice. If in doubt, ask your supplier for their stated clearance. 

Common Sizing Mistakes to Avoid 

A few simple errors cause most problems: 

  • Confusing structural opening vs rooflight size and ordering the wrong dimension. 
  • Measuring after plasterboarding, when the true opening is hidden. 
  • Using one measurement instead of three, so a tapered opening goes unnoticed. 
  • Forgetting upstand height and roof build-up. 
  • Mixing inches and millimetres. UK suppliers work in mm. 

A quick double-check against the manufacturer’s drawing prevents almost all of these. 

Final Thoughts  

Accurate measuring protects your budget, your timeline and your roof. Remember the key points from this roof window sizes guide: know your structural opening, check the kerb dimensions and measure before plasterboarding. Whether you pick standard rooflight sizes UK stockists offer or a bespoke unit, confirm everything in millimetres. Unsure about a measurement? Our team is happy to help before you order. 

Frequently Asked Questions

What does a roof window sizes guide mean by structural opening?
It is the clear hole in your roof timbers, formed by trimmer timbers. Rooflights are normally ordered to fit this opening.
How to measure for a skylight on a flat roof?
Measure width and length at three points in mm, check both diagonals and note the upstand height. Compare the results with the product drawing.
What is the difference in structural opening vs rooflight size?
The structural opening is the hole in the timber. The rooflight size often refers to the outer frame, which is usually larger.
What are standard rooflight sizes UK builders use?
Common stock sizes vary by supplier, but many are based on neat metric dimensions that suit 400mm and 600mm joist spacing. Check current ranges.
When should I choose custom skylight dimensions?
Choose custom sizes for unusual openings, period roofs or wide glazing runs where standard units do not fit well.
Should I measure before or after plasterboarding?
Always before. Structural dimensions are hard to check once boards and finishes are installed.
What tolerance should I allow around a rooflight?
Many manufacturers suggest a few millimetres per side. Follow your supplier’s drawing for the exact clearance.
Does BS 8213-4 apply to rooflight installation?
Yes. It is the UK code of practice for installing windows, doors and roof windows, and it supports good fitting and tolerances.

Note: The information provided in this blog is accurate as of 13 Nov 2026